Skip to content

ConformLoad

ConformLoad represent loads that follow a daily load change pattern where the pattern can be used to scale the load with a system load.

URI: cim:ConformLoad
Type: Class

 classDiagram
    class ConformLoad
    click ConformLoad href "../ConformLoad"
      EnergyConsumer <|-- ConformLoad
        click EnergyConsumer href "../EnergyConsumer"

      ConformLoad : Equipment.aggregate

      ConformLoad : ConductingEquipment.BaseVoltage

          ConformLoad --> BaseVoltage : ConductingEquipment.BaseVoltage
          click BaseVoltage href "../BaseVoltage"

      ConformLoad : IdentifiedObject.description

      ConformLoad : Equipment.EquipmentContainer

          ConformLoad --> EquipmentContainer : Equipment.EquipmentContainer
          click EquipmentContainer href "../EquipmentContainer"

      ConformLoad : ConformLoad.LoadGroup

          ConformLoad --> ConformLoadGroup : ConformLoad.LoadGroup
          click ConformLoadGroup href "../ConformLoadGroup"

      ConformLoad : EnergyConsumer.LoadResponse

          ConformLoad --> LoadResponseCharacteristic : EnergyConsumer.LoadResponse
          click LoadResponseCharacteristic href "../LoadResponseCharacteristic"

      ConformLoad : IdentifiedObject.mRID

      ConformLoad : IdentifiedObject.name

      ConformLoad : Equipment.normallyInService

      ConformLoad : EnergyConsumer.pfixed

      ConformLoad : EnergyConsumer.pfixedPct

      ConformLoad : EnergyConsumer.qfixed

      ConformLoad : EnergyConsumer.qfixedPct

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
LoadGroup cim:ConformLoad.LoadGroup 1
ConformLoadGroup
Group of this ConformLoad direct
pfixed cim:EnergyConsumer.pfixed 0..1
ActivePower
Active power of the load that is a fixed quantity and does not vary as load g... EnergyConsumer
pfixedPct cim:EnergyConsumer.pfixedPct 0..1
PerCent
Fixed active power as a percentage of load group fixed active power EnergyConsumer
qfixed cim:EnergyConsumer.qfixed 0..1
ReactivePower
Reactive power of the load that is a fixed quantity and does not vary as load... EnergyConsumer
qfixedPct cim:EnergyConsumer.qfixedPct 0..1
PerCent
Fixed reactive power as a percentage of load group fixed reactive power EnergyConsumer
LoadResponse cim:EnergyConsumer.LoadResponse 0..1
LoadResponseCharacteristic
The load response characteristic of this load EnergyConsumer
BaseVoltage cim:ConductingEquipment.BaseVoltage 0..1
BaseVoltage
Base voltage of this conducting equipment ConductingEquipment
aggregate cim:Equipment.aggregate 0..1
boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
normallyInService cim:Equipment.normallyInService 0..1
boolean
Specifies the availability of the equipment under normal operating conditions Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1
EquipmentContainer
Container of this equipment Equipment
mRID cim:IdentifiedObject.mRID 1
string
Master resource identifier issued by a model authority IdentifiedObject
description cim:IdentifiedObject.description 0..1
string
The description is a free human readable text describing or naming the object IdentifiedObject
name cim:IdentifiedObject.name 1
string
The name is any free human readable and possibly non unique text naming the o... IdentifiedObject

Comments

    • The definition of the real and reactive power injections for an EnergyConsumer can be done using different sets of attributes. In the simplest case, the injections can be defined directly using only the attributes pfixed and qfixed.- The injections for a ConformLoad can be defined as a percentage of the ConformLoadGroup with the attributes pfixedPct and qfixedPct. In this case, the associated ConformLoadGroup would have to have an associated ConformLoadSchedule.- See EnergyConsumer for specific notes about inherited attributes.

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/2020/CPSM-CoreEquipment#

Mappings

Mapping Type Mapped Value
self cim:ConformLoad
native this:ConformLoad