A generating unit whose prime mover is a hydraulic turbine (e.g., Francis, Pelton, Kaplan).

URI: cim:HydroGeneratingUnit
Type: Class

 classDiagram
    class HydroGeneratingUnit
    click HydroGeneratingUnit href "../HydroGeneratingUnit"
      GeneratingUnit <|-- HydroGeneratingUnit
        click GeneratingUnit href "../GeneratingUnit"

      HydroGeneratingUnit : Equipment.aggregate

      HydroGeneratingUnit : IdentifiedObject.description

      HydroGeneratingUnit : HydroGeneratingUnit.dropHeight

      HydroGeneratingUnit : Equipment.EquipmentContainer

          HydroGeneratingUnit --> EquipmentContainer : Equipment.EquipmentContainer
          click EquipmentContainer href "../EquipmentContainer"

      HydroGeneratingUnit : GeneratingUnit.governorSCD

      HydroGeneratingUnit : HydroGeneratingUnit.HydroPowerPlant

          HydroGeneratingUnit --> HydroPowerPlant : HydroGeneratingUnit.HydroPowerPlant
          click HydroPowerPlant href "../HydroPowerPlant"

      HydroGeneratingUnit : GeneratingUnit.initialP

      HydroGeneratingUnit : GeneratingUnit.longPF

      HydroGeneratingUnit : GeneratingUnit.maximumAllowableSpinningReserve

      HydroGeneratingUnit : GeneratingUnit.maxOperatingP

      HydroGeneratingUnit : GeneratingUnit.minOperatingP

      HydroGeneratingUnit : IdentifiedObject.mRID

      HydroGeneratingUnit : IdentifiedObject.name

      HydroGeneratingUnit : GeneratingUnit.nominalP

      HydroGeneratingUnit : Equipment.normallyInService

      HydroGeneratingUnit : GeneratingUnit.ratedGrossMaxP

      HydroGeneratingUnit : GeneratingUnit.ratedGrossMinP

      HydroGeneratingUnit : GeneratingUnit.ratedNetMaxP

      HydroGeneratingUnit : GeneratingUnit.shortPF

      HydroGeneratingUnit : GeneratingUnit.startupCost

      HydroGeneratingUnit : GeneratingUnit.startupTime

      HydroGeneratingUnit : GeneratingUnit.totalEfficiency

      HydroGeneratingUnit : GeneratingUnit.variableCost

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
dropHeight cim:HydroGeneratingUnit.dropHeight 0..1
Length
The height water drops from the reservoir mid-point to the turbine direct
HydroPowerPlant cim:HydroGeneratingUnit.HydroPowerPlant 0..1
HydroPowerPlant
The hydro generating unit belongs to a hydro power plant direct
governorSCD cim:GeneratingUnit.governorSCD 0..1
PerCent
Governor Speed Changer Droop GeneratingUnit
initialP cim:GeneratingUnit.initialP 1
ActivePower
Default initial active power which is used to store a powerflow result for t... GeneratingUnit
longPF cim:GeneratingUnit.longPF 0..1
float
Generating unit long term economic participation factor GeneratingUnit
maximumAllowableSpinningReserve cim:GeneratingUnit.maximumAllowableSpinningReserve 0..1
ActivePower
Maximum allowable spinning reserve GeneratingUnit
maxOperatingP cim:GeneratingUnit.maxOperatingP 1
ActivePower
This is the maximum operating active power limit the dispatcher can enter for... GeneratingUnit
minOperatingP cim:GeneratingUnit.minOperatingP 1
ActivePower
This is the minimum operating active power limit the dispatcher can enter for... GeneratingUnit
nominalP cim:GeneratingUnit.nominalP 0..1
ActivePower
The nominal power of the generating unit GeneratingUnit
ratedGrossMaxP cim:GeneratingUnit.ratedGrossMaxP 0..1
ActivePower
The unit's gross rated maximum capacity (book value) GeneratingUnit
ratedGrossMinP cim:GeneratingUnit.ratedGrossMinP 0..1
ActivePower
The gross rated minimum generation level which the unit can safely operate at... GeneratingUnit
ratedNetMaxP cim:GeneratingUnit.ratedNetMaxP 0..1
ActivePower
The net rated maximum capacity determined by subtracting the auxiliary power ... GeneratingUnit
shortPF cim:GeneratingUnit.shortPF 0..1
float
Generating unit short term economic participation factor GeneratingUnit
startupCost cim:GeneratingUnit.startupCost 0..1
Money
The initial startup cost incurred for each start of the GeneratingUnit GeneratingUnit
startupTime cim:GeneratingUnit.startupTime 0..1
Seconds
Time it takes to get the unit on-line, from the time that the prime mover mec... GeneratingUnit
totalEfficiency cim:GeneratingUnit.totalEfficiency 0..1
PerCent
The efficiency of the unit in converting the fuel into electrical energy GeneratingUnit
variableCost cim:GeneratingUnit.variableCost 0..1
Money
The variable cost component of production per unit of ActivePower GeneratingUnit
aggregate cim:Equipment.aggregate 0..1
boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
normallyInService cim:Equipment.normallyInService 0..1
boolean
Specifies the availability of the equipment under normal operating conditions Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1
EquipmentContainer
Container of this equipment Equipment
mRID cim:IdentifiedObject.mRID 1
string
Master resource identifier issued by a model authority IdentifiedObject
description cim:IdentifiedObject.description 0..1
string
The description is a free human readable text describing or naming the object IdentifiedObject
name cim:IdentifiedObject.name 1
string
The name is any free human readable and possibly non unique text naming the o... IdentifiedObject

Comments

    • The attributes governorSCD, maximumAllowableSpinningReserve, nominalP, startupCost, and variableCost are not required.

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/2020/CPSM-CoreEquipment#

Mappings

Mapping Type Mapped Value
self cim:HydroGeneratingUnit
native this:HydroGeneratingUnit