HydroGeneratingUnit
A generating unit whose prime mover is a hydraulic turbine (e.g., Francis, Pelton, Kaplan).
URI: cim:HydroGeneratingUnit
Type: Class
classDiagram
class HydroGeneratingUnit
click HydroGeneratingUnit href "../HydroGeneratingUnit"
GeneratingUnit <|-- HydroGeneratingUnit
click GeneratingUnit href "../GeneratingUnit"
HydroGeneratingUnit : Equipment.aggregate
HydroGeneratingUnit : IdentifiedObject.description
HydroGeneratingUnit : HydroGeneratingUnit.dropHeight
HydroGeneratingUnit : Equipment.EquipmentContainer
HydroGeneratingUnit --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
HydroGeneratingUnit : GeneratingUnit.governorSCD
HydroGeneratingUnit : HydroGeneratingUnit.HydroPowerPlant
HydroGeneratingUnit --> HydroPowerPlant : HydroGeneratingUnit.HydroPowerPlant
click HydroPowerPlant href "../HydroPowerPlant"
HydroGeneratingUnit : GeneratingUnit.initialP
HydroGeneratingUnit : GeneratingUnit.longPF
HydroGeneratingUnit : GeneratingUnit.maximumAllowableSpinningReserve
HydroGeneratingUnit : GeneratingUnit.maxOperatingP
HydroGeneratingUnit : GeneratingUnit.minOperatingP
HydroGeneratingUnit : IdentifiedObject.mRID
HydroGeneratingUnit : IdentifiedObject.name
HydroGeneratingUnit : GeneratingUnit.nominalP
HydroGeneratingUnit : Equipment.normallyInService
HydroGeneratingUnit : GeneratingUnit.ratedGrossMaxP
HydroGeneratingUnit : GeneratingUnit.ratedGrossMinP
HydroGeneratingUnit : GeneratingUnit.ratedNetMaxP
HydroGeneratingUnit : GeneratingUnit.shortPF
HydroGeneratingUnit : GeneratingUnit.startupCost
HydroGeneratingUnit : GeneratingUnit.startupTime
HydroGeneratingUnit : GeneratingUnit.totalEfficiency
HydroGeneratingUnit : GeneratingUnit.variableCost
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- GeneratingUnit
- HydroGeneratingUnit
- GeneratingUnit
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
dropHeight | cim:HydroGeneratingUnit.dropHeight | 0..1 Length |
The height water drops from the reservoir mid-point to the turbine | direct |
HydroPowerPlant | cim:HydroGeneratingUnit.HydroPowerPlant | 0..1 HydroPowerPlant |
The hydro generating unit belongs to a hydro power plant | direct |
governorSCD | cim:GeneratingUnit.governorSCD | 0..1 PerCent |
Governor Speed Changer Droop | GeneratingUnit |
initialP | cim:GeneratingUnit.initialP | 1 ActivePower |
Default initial active power which is used to store a powerflow result for t... | GeneratingUnit |
longPF | cim:GeneratingUnit.longPF | 0..1 float |
Generating unit long term economic participation factor | GeneratingUnit |
maximumAllowableSpinningReserve | cim:GeneratingUnit.maximumAllowableSpinningReserve | 0..1 ActivePower |
Maximum allowable spinning reserve | GeneratingUnit |
maxOperatingP | cim:GeneratingUnit.maxOperatingP | 1 ActivePower |
This is the maximum operating active power limit the dispatcher can enter for... | GeneratingUnit |
minOperatingP | cim:GeneratingUnit.minOperatingP | 1 ActivePower |
This is the minimum operating active power limit the dispatcher can enter for... | GeneratingUnit |
nominalP | cim:GeneratingUnit.nominalP | 0..1 ActivePower |
The nominal power of the generating unit | GeneratingUnit |
ratedGrossMaxP | cim:GeneratingUnit.ratedGrossMaxP | 0..1 ActivePower |
The unit's gross rated maximum capacity (book value) | GeneratingUnit |
ratedGrossMinP | cim:GeneratingUnit.ratedGrossMinP | 0..1 ActivePower |
The gross rated minimum generation level which the unit can safely operate at... | GeneratingUnit |
ratedNetMaxP | cim:GeneratingUnit.ratedNetMaxP | 0..1 ActivePower |
The net rated maximum capacity determined by subtracting the auxiliary power ... | GeneratingUnit |
shortPF | cim:GeneratingUnit.shortPF | 0..1 float |
Generating unit short term economic participation factor | GeneratingUnit |
startupCost | cim:GeneratingUnit.startupCost | 0..1 Money |
The initial startup cost incurred for each start of the GeneratingUnit | GeneratingUnit |
startupTime | cim:GeneratingUnit.startupTime | 0..1 Seconds |
Time it takes to get the unit on-line, from the time that the prime mover mec... | GeneratingUnit |
totalEfficiency | cim:GeneratingUnit.totalEfficiency | 0..1 PerCent |
The efficiency of the unit in converting the fuel into electrical energy | GeneratingUnit |
variableCost | cim:GeneratingUnit.variableCost | 0..1 Money |
The variable cost component of production per unit of ActivePower | GeneratingUnit |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
Comments
-
- The attributes governorSCD, maximumAllowableSpinningReserve, nominalP, startupCost, and variableCost are not required.
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/2020/CPSM-CoreEquipment#
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:HydroGeneratingUnit |
native | this:HydroGeneratingUnit |