LoadBreakSwitch
A mechanical switching device capable of making, carrying, and breaking currents under normal operating conditions.
URI: cim:LoadBreakSwitch
Type: Class
classDiagram
class LoadBreakSwitch
click LoadBreakSwitch href "../LoadBreakSwitch"
ProtectedSwitch <|-- LoadBreakSwitch
click ProtectedSwitch href "../ProtectedSwitch"
LoadBreakSwitch : Equipment.aggregate
LoadBreakSwitch : ConductingEquipment.BaseVoltage
LoadBreakSwitch --> BaseVoltage : ConductingEquipment.BaseVoltage
click BaseVoltage href "../BaseVoltage"
LoadBreakSwitch : IdentifiedObject.description
LoadBreakSwitch : Equipment.EquipmentContainer
LoadBreakSwitch --> EquipmentContainer : Equipment.EquipmentContainer
click EquipmentContainer href "../EquipmentContainer"
LoadBreakSwitch : IdentifiedObject.mRID
LoadBreakSwitch : IdentifiedObject.name
LoadBreakSwitch : Equipment.normallyInService
LoadBreakSwitch : Switch.normalOpen
LoadBreakSwitch : Switch.ratedCurrent
LoadBreakSwitch : Switch.retained
Inheritance
- IdentifiedObject
- PowerSystemResource
- Equipment
- ConductingEquipment
- Switch
- ProtectedSwitch
- LoadBreakSwitch
- ProtectedSwitch
- Switch
- ConductingEquipment
- Equipment
- PowerSystemResource
Attributes
Name | URI | Cardinality and Range | Description | Inheritance |
---|---|---|---|---|
normalOpen | cim:Switch.normalOpen | 1 boolean |
The attribute is used in cases when no Measurement for the status value is pr... | Switch |
ratedCurrent | cim:Switch.ratedCurrent | 0..1 CurrentFlow |
The maximum continuous current carrying capacity in amps governed by the devi... | Switch |
retained | cim:Switch.retained | 1 boolean |
Branch is retained in the topological solution | Switch |
BaseVoltage | cim:ConductingEquipment.BaseVoltage | 0..1 BaseVoltage |
Base voltage of this conducting equipment | ConductingEquipment |
aggregate | cim:Equipment.aggregate | 0..1 boolean |
The aggregate flag provides an alternative way of representing an aggregated ... | Equipment |
normallyInService | cim:Equipment.normallyInService | 0..1 boolean |
Specifies the availability of the equipment under normal operating conditions | Equipment |
EquipmentContainer | cim:Equipment.EquipmentContainer | 0..1 EquipmentContainer |
Container of this equipment | Equipment |
mRID | cim:IdentifiedObject.mRID | 1 string |
Master resource identifier issued by a model authority | IdentifiedObject |
description | cim:IdentifiedObject.description | 0..1 string |
The description is a free human readable text describing or naming the object | IdentifiedObject |
name | cim:IdentifiedObject.name | 1 string |
The name is any free human readable and possibly non unique text naming the o... | IdentifiedObject |
Identifier and Mapping Information
Schema Source
- from schema: http://iec.ch/TC57/2020/CPSM-CoreEquipment#
Mappings
Mapping Type | Mapped Value |
---|---|
self | cim:LoadBreakSwitch |
native | this:LoadBreakSwitch |