Skip to content

PowerTransformer

An electrical device consisting of two or more coupled windings, with or without a magnetic core, for introducing mutual coupling between electric circuits. Transformers can be used to control voltage and phase shift (active power flow).A power transformer may be composed of separate transformer tanks that need not be identical.A power transformer can be modelled with or without tanks and is intended for use in both balanced and unbalanced representations. A power transformer typically has two terminals, but may have one (grounding), three or more terminals.The inherited association ConductingEquipment.BaseVoltage should not be used. The association from TransformerEnd to BaseVoltage should be used instead.

URI: cim:PowerTransformer
Type: Class

 classDiagram
    class PowerTransformer
    click PowerTransformer href "../PowerTransformer"
      Equipment <|-- PowerTransformer
        click Equipment href "../Equipment"

      PowerTransformer : Equipment.aggregate

      PowerTransformer : IdentifiedObject.description

      PowerTransformer : Equipment.EquipmentContainer

          PowerTransformer --> EquipmentContainer : Equipment.EquipmentContainer
          click EquipmentContainer href "../EquipmentContainer"

      PowerTransformer : IdentifiedObject.mRID

      PowerTransformer : IdentifiedObject.name

      PowerTransformer : Equipment.normallyInService

Inheritance

Attributes

Name URI Cardinality and Range Description Inheritance
aggregate cim:Equipment.aggregate 0..1
boolean
The aggregate flag provides an alternative way of representing an aggregated ... Equipment
normallyInService cim:Equipment.normallyInService 0..1
boolean
Specifies the availability of the equipment under normal operating conditions Equipment
EquipmentContainer cim:Equipment.EquipmentContainer 0..1
EquipmentContainer
Container of this equipment Equipment
mRID cim:IdentifiedObject.mRID 1
string
Master resource identifier issued by a model authority IdentifiedObject
description cim:IdentifiedObject.description 0..1
string
The description is a free human readable text describing or naming the object IdentifiedObject
name cim:IdentifiedObject.name 1
string
The name is any free human readable and possibly non unique text naming the o... IdentifiedObject

Usages

used by used in type used
PowerTransformerEnd PowerTransformer range PowerTransformer

Comments

  • A PowerTransformer can be either two winding or three winding.- A two winding transformer has two PowerTransformerEnds and two associated Terminals.- A three winding transformer has three PowerTransformerEnds and three associated Terminals.

Identifier and Mapping Information

Schema Source

  • from schema: http://iec.ch/TC57/2020/CPSM-CoreEquipment#

Mappings

Mapping Type Mapped Value
self cim:PowerTransformer
native this:PowerTransformer